top of page
Antibody System Anti-Cosibelimab ELISA Kit

Antibody System Anti-Cosibelimab ELISA Kit

Overview

This enzyme-linked immunosorbent assay (ELISA) kit is engineered for the precise quantitative determination of Anti-Cosibelimab antibody concentrations in serum and plasma samples. Cosibelimab is a high-affinity, fully human monoclonal IgG1 antibody that targets Programmed Death-Ligand 1 (PD-L1), effectively blocking its interaction with the PD-1 receptor to re-activate suppressed T-cell-mediated anti-tumor immune responses, particularly in advanced cutaneous squamous cell carcinoma. This specialized ELISA platform is optimized for detecting and quantifying anti-drug antibodies (ADAs) generated against Cosibelimab. It serves as a vital analytical instrument for clinical investigators, immunologists, and pharmacologists analyzing long-term immunogenicity profiles, drug clearance variations, and the overall safety and efficacy parameters of PD-L1-targeted checkpoint inhibition therapies.

 

DATASHEET

  • PRODUCT INFO

    Principle of the Assay

    This assay utilizes a high-performance, solid-phase quantitative sandwich enzyme immunoassay technique (bridging format) to measure specific anti-drug antibody levels:

    • Target Capture: Recombinant Cosibelimab is uniformly pre-coated onto the solid-phase surface of a 96-well microplate.

    • Specific Binding: Calibrated standards or unknown biological samples are pipetted directly into the microwells. Endogenous Anti-Cosibelimab antibodies present in the sample are bound and captured by the immobilized Cosibelimab proteins.

    • Bridging Conjugation: Unbound matrix elements are removed via a rigorous wash cycle. A biotin-labeled Cosibelimab tracer solution is introduced into the wells, binding to the open antigen-binding sites of the captured Anti-Cosibelimab target, effectively forming an immune bridging complex.

    • Enzyme Complexing: Following another wash step to clear unbound tracer, Streptavidin conjugated to Horseradish Peroxidase (Streptavidin-HRP) is added to bind specifically to the biotinylated domains.

    • Signal Amplification and Readout: After a final wash to remove excess enzyme reagent, a colorimetric substrate solution is added to initiate enzymatic signal development. Because this is a bridging sandwich assembly, the resulting color intensity develops in direct proportion to the concentration of Anti-Cosibelimab bound in the initial step. The reaction is terminated with a stop solution, and absorbance is quantified spectrophotometrically.

    Key Features and Performance Metrics

    • Sensitive Detection Capability: Exhibits an analytical sensitivity down to 133.24 ng/mL, facilitating the early tracking of low-level anti-drug antibody formations.

    • Extended Quantitative Range: Delivers a wide dynamic tracking range from 156.25 ng/mL to 10,000 ng/mL to accommodate diverse sample concentration tiers without immediate saturation.

    • Exceptional Intra-Assay Precision: Demonstrates excellent target reproducibility with a Coefficient of Variation (CV) of less than 10 percent, verified through sixteen separate replicate evaluations across three samples of known concentration on a single test plate.

    • High Inter-Assay Uniformity: Confirms outstanding day-to-day and batch-to-batch experimental reliability with a CV of less than 15 percent, validated across twenty-four distinct assay runs using three independent reference concentration samples.

    Technical Specifications

    • Catalog No.: KAJ70104

    • Assay Configuration: Quantitative Bridging Sandwich Enzyme Immunoassay

    • Targeted Biomarker: Anti-Cosibelimab (Anti-Drug Antibodies / ADA)

    • Validated Matrices: Serum and Plasma

    • Assay Range: 156.25 to 10,000 ng/mL

    • Analytical Sensitivity: 133.24 ng/mL

    • Solid-Phase Target: Recombinant Cosibelimab

    • Detection Enzyme Layer: Biotin-Cosibelimab / Streptavidin-HRP Conjugate

    Applications and Workflow Summary

    This bridging sandwich ELISA platform is highly optimized for therapeutic drug immunogenicity monitoring and downstream pharmacokinetic profiling. Investigators should observe the following guidelines:

    • Dilution and Layout: Unknown serum or plasma matrices must be screened alongside the provided reference standards. Samples exhibiting target concentrations exceeding the maximum range of 10,000 ng/mL must be diluted empirically in standard assay matrix buffer prior to running the assay.

    • Analysis Requirements: To achieve absolute quantification accuracy, investigators must generate a standard curve simultaneously during every plate run, plotting standard absorbance profiles against log-transformed concentration values.

    Handling, Stability and Storage

    • Kit Shipping: Distributed under secure, temperature-controlled conditions on blue ice or chilled gel packs to safeguard protein matrix and enzyme binding configurations.

    • Operational Stability: Built with high-grade components to guarantee consistent, low-decay signal retention over a standard six-month framework when kept at the manufacturer-specified storage parameters.

    • Storage Guidance: Keep the complete kit stored strictly at the recommended refrigeration temperature upon receipt. Ensure that unused microplate wells remain sealed within their original desiccant pouch to guard against moisture compromise.

Heading 6

Related Products

bottom of page