Labmate LMCG-A100 Gas Chromatograph
Discover precision and reliability with the Labmate LMCG-A100 Gas Chromatograph, now available at winselluma, your authorized distributor. The LMCG-A100 is engineered for advanced gas analysis, delivering exceptional accuracy and performance for various industrial applications. As an authorized distributor, winselluma ensures genuine products, superior customer support, and competitive pricing. Trust in winselluma to provide the best in analytical instrumentation. Enhance your lab's capabilities with the Labmate LMCG-A100 today.
Product Info
The Labmate LMCG-A100 Gas Chromatograph is engineered for precise separation and identification of chemical components within gas or liquid mixtures. Its robust design and advanced features cater to a wide array of analytical applications.
Key Features:
- Wide Operating Temperature Range: Offers a versatile temperature range from +4°C to 450°C (ambient), with options for LN₂ cooling down to -80°C and CO₂ cooling to -40°C, both up to 450°C.
- Advanced Temperature Control: Features a stable gradient control, multi-step programming (32-step gradient with 33 fixed platforms), and rapid gradient cooling.
- High-Performance Column Oven: Equipped with a large column oven (≥15 L) ensuring stable and consistent temperature.
- Intuitive Touchscreen Interface: Incorporates a 7-inch touchscreen for real-time display, method editing, and convenient remote operation.
- Flexible Data Handling: Direct report export capability in Excel and Word formats streamlines data sharing and documentation.
- Superior Cooling Performance: Achieves rapid cooling from 450°C to 50°C in under 3.5 minutes.
- Multiple Inlets and Detectors: Accommodates up to 4 inlets and 5 detectors for comprehensive analysis.
- Precision Gas Control: Offers precise pressure control with an accuracy of ±0.001 psi and a split ratio range of 1:2500.
- Flame-out Protection: Ensures safe operation.
- High-Speed Data Collection: For accurate and reliable results.
- Automatic Drift Correction: Maintains baseline stability.
- Batch Data Processing: Simplifies analysis of multiple samples.
- Remote Control: Controllable via Wi-Fi, PC, mobile, or tablet.
- Data Protection: Features local storage, USB sync, and crash recovery.
Feature Specification Column Oven Volume ≥15 L Operating Temperature Range +4 ℃ to 450 ℃ (ambient); LN₂: -80 ℃ to 450 ℃; CO₂: -40 ℃ to 450 ℃ Temperature Setting Accuracy ≥0.01 ℃ Temperature Programs 32-step gradient; 33 fixed platforms; gradient cooling Maximum Heating Rate ≥120 ℃/min Maximum Running Time 999.9 min Cooling Time 450 ℃ to 50 ℃ in less than 3.5 min Fan Speed Levels Low, medium, high, extreme Number Of Inlets 4 Inlet Max Temperature 450 ℃ Column Head Pressure Range 0 to 100 psi (upgradeable to 150 psi) Pressure Control Accuracy ±0.001 psi Split Ratio Range 1:2500 Carrier Gas Flow Range 0 to 100 mL/min (N₂, H₂, He); total: N₂ (0 to 500 mL/min), H₂/He (0 to 1250 mL/min) Number Of Detectors 5 Detector Type FID (Hydrogen Flame Ionization), TCD (Thermal Conductivity) FID Max Temperature 450 ℃ FID Min Detection Limit ≤1.2 pg C/s FID Dynamic Range ≥10⁷ (±10%) TCD Max Temperature 400 ℃ TCD Min Detection Limit ≤700 pg propane/mL TCD Sensitivity ≥800000 mV mL/mg TCD Dynamic Range ≥10⁵ TCD Equilibration Time Less than 5 minutes Valve System 10 valves Display 7-inch color touch screen Control Interface Wi-Fi / PC/mobile/tablet remote control Data Protection Local storage, USB sync, crash recovery Report Export Excel, Word compatible Dimension 610×520×850 mm Packing Dimension 1200×800×930 mm Net Weight 60 kg Gross Weight 90 kg Standard Accessories:
- LMCG-A100-C1: Chromatographic Workstation
- LMCG-A100-C2: Packed Column Inlet
- LMCG-A100-C3: Valve Box and Control System
- LMCG-A100-C4: Nickel Conversion Device
- LMCG-A100-C5: TCD Connection Components
- LMCG-A100-C6: FID Connection Components
- LMCG-A100-C7: Chromatographic Column 1
- LMCG-A100-C8: Chromatographic Column 2
- LMCG-A100-C9: Computer
- LMCG-A100-D1: FID Detector
- LMCG-A100-D2: TCD Detector
- LMCG-A100-P1: Seven-Component Power Analysis Method Package
- LMCG-A100-T1: Installation and Debugging Tool Kit
- LMCG-A100-T2: Packed Column Inlet Tool Kit
- LMCG-A100-T3: FID Tool Kit
- LMCG-A100-T4: TCD Tool Kit
- LMCG-A100-T5: Gas Trap
- LMCG-A100-V1: Automatic Six-Way Injection Valve
Optional Accessories:
- LMCG-A100-D3: Mechanical Oscillation Degassing Device
- LMCG-A100-D4: Fully Automatic Vacuum Degassing Device
- LMCG-A100-P2: Pressure Reducing Valve
Applications:
The Labmate LMCG-A100 is indispensable for analyzing chemical components in gases and liquids across various industries, including:
- Petrochemical
- Pharmaceutical
- Food Safety
- Environmental Monitoring
- Quality Control

















