Labmate Gas Chromatography LMCG-101
Discover precise and reliable analysis with the Labmate Gas Chromatography LMCG-101, a top-tier instrument now available through winselluma. As an authorized distributor, winselluma provides expert service and support, ensuring your investment in cutting-edge technology is well-placed. The LMCG-101 delivers exceptional performance for a diverse range of applications, making it ideal for laboratories seeking accuracy and consistency. Trust winselluma's commitment to quality and customer satisfaction to elevate your analytical capabilities with this advanced gas chromatography solution.
Product Info
Labmate Gas Chromatography LMCG-101 has a temperature range of 7°C to 450°C. It ensures stable thermal control and efficient column performance. Equipped with an advanced detector that delivers consistent results. Integrated with an intuitive touchscreen that allows seamless operation. Our Gas Chromatography supports analytical settings in pharmaceuticals, petrochemicals, and environmental testing.
Specifications
Temperature Range 7ºC to 420ºC Temperature Accuracy ±0.02ºC Cooling Time 350°C to 100°C ≤ 3 min 400°C to 50°C in 8-10 min at 25°C ambient Programmed Temperature Range 0.1℃ to 80℃/min Program Ramps 20 Ramps FID Detection Time ≤8×10-12 g/s (n-hexadecane) FID Baseline Drift ≤1.5×10-13 A/h FID Baseline Noise ≤3×10-14 A FID Linearity ≥106 TCD Maximum Operating Temperature 400ºC TCD Temperature Accuracy ±0.1ºC TCD Detector Sensitivity ≥ 10000 mV × mL / mg (n-Hexadecane) TCD Baseline Noise ≤20uv TCD Baseline Drift ≤100uv/30 min TCD Linear Dynamic Range ≥104 FPD Detection ≤8×10‐13 g/s(P); ≤8×10‐11 g/s(S) FPD Baseline Drift ≤2×10‐11 A/30 min FPD Baseline Noise ≤5×10‐12 A NPD Detection Limit ≤5×10-12 g/s(N) (Azobenzene) ≤5×10-13 g/s(P) (Malathion) ECD Detection Limit ≤3×10-14 g/ml ECD Baseline Drift ≤ 100 μV/30 min ECD Baseline Noise ≤40μV Internal Dimension (W×D×H) 284×280×241 mm External Dimension (W×D×H) 340×345×281 mm Features
- Computer-controlled system
- Multistage temperature control
- Real-time status monitoring
- Rapid heat-up and cool-down
- Dual injector operation
- Independent signal output
Standard Accessories
M6 Software
Optional Accessories
Model No. Accessory Quantity Unit LMCG-101-GC1 Split/Non-split capillary injector 1 Each LMCG-101-GC2 Flame Ionization Detector (FID) 1 Each LMCG-101-GC3 Thermal Conductivity Detector (TCD) 1 Each LMCG-101-GC4 Flame Photometric Detector (FPD) 1 Each LMCG-101-GC5 Electron Capture Detector (ECD) 1 Each LMCG-101-GC6 Nitrogen Phosphorus Detector (NPD) 1 Each LMCG-101-GC7 Autosampler 22 places 1 Each LMCG-101-GC8 Autosampler 156 places 1 Each Applications
Labmate Gas Chromatography LMCG-101 is employed in pharmaceuticals, petrochemicals, food safety, and environmental analysis. It ensures reliable compound separation and detection in complex mixtures.