Labmate Atomic Absorption Spectrophotometer LMAAS-A109
Labmate Atomic Absorption Spectrophotometer LMAAS-A109 provides a Cu detection limit of less than 0.006 µg/mL. Designed with dual atomization modes, it supports both flame and graphite furnace analysis. The instrument incorporates a single-beam optical system and advanced background correction using D2 and self-absorption methods. Multiple safety sensors, including gas flow, pressure, flame, and furnace monitoring, ensure reliable operation.
Product Info
Key Features
-
Dual atomization: Flame and Graphite Furnace
-
Single-beam optical system with Czerny-Turner monochromator (350 mm focal length)
-
Wavelength range: 190–900 nm, accuracy ±0.2 nm, repeatability ±0.1 nm
-
Holographic diffraction grating, 1800 lines/mm
-
Automated 8-lamp turret and automated slit selection
-
Transmittance, absorbance, and concentration reading modes
-
D2 and self-absorption background correction
-
High-efficiency glass nebulizer, automatic burner adjustment, corrosion-resistant premix chamber
-
Speed-adjustable external gas flow and auto acetylene/air flow control
-
Safety protections: water flow, argon pressure, furnace temperature, graphite tube installation, flame sensor, gas leak and pressure sensors
-
RGWIN AAS software for analysis, QA/QC, and RS-232 communication
Applications
-
Petrochemical and metallurgical analysis
-
Mining and geological sample testing
-
Material science and industrial metal analysis
-
Food, pharmaceutical, and chemical quality control
-
Ultra-trace and high-concentration elemental detection
Technical Highlights
Specification Details Optical Type Single beam Atomizer Flame and Graphite furnace Monochromator Czerny-Turner, 350 mm focal length Wavelength Range 190–900 nm Wavelength Accuracy ±0.2 nm Wavelength Repeatability ±0.1 nm Grating Holographic, 1800 lines/mm Slits 0.1, 0.2, 0.4, 0.7, 1.4, 2.0 nm Lamp Holder Automated 8-lamp turret Detector Wide-range UV-sensitive photomultiplier tube Reading Mode T, A, C Photometric Range 0–125%, -0.1–3.00 A Static Baseline Drift (Cu) <0.003 A/30 min Dynamic Baseline Drift <0.005 A/15 min Background Correction D2 and self-absorption Characteristic Concentration Cu <0.035 µg/mL Characteristic Mass Cd <0.8 pg, Cu <20 pg Detection Limit Flame Analysis: Cu <0.006 µg/mL Repeatability (Cu) Flame Analysis: RSD <0.6% Burner Head 100 mm titanium alloy Acetylene Flow Control Auto 12-level Air Flow Control Auto 4-level Ramp & Holding Time 1–255 s Heating Rate Max linear 2000 °C/s Heating Method Light-controlled, Time-controlled, General heating Gas Flow Rate Inside Tube 1 L/min Gas Flow Rate Outside Tube 0, 50, 200, 250 mL/min Communication Port RS-232 Working Environment 10–35 °C, <85% RH Power Supply 110/220 V, 50/60 Hz Dimensions (W×D×H) 850×650×550 mm Weight 100 kg Standard Accessories
-
Main unit, power cable, data cable, screwdriver
-
Cu & Cd hollow cathode lamps
-
Air compressor, acetylene & air tubes, ignition filaments (5 pcs)
-
USB with manual/software, drain tube, fuses, argon pressure valve connector
-
Graphite tubes (5 pcs), high-power socket, argon tube, pipette & tips, cooling water tube
-
Graphite furnace camera connection cable
Optional Accessories
-
Hybrid generator, circulation cooling water system, quiet air compressor
-
50 mm nitrous oxide burner, additional graphite tubes, glass nebulizer
-
Auto samplers (2 models), N₂O module, deuterium lamp, graphite tube camera
-
Hollow cathode lamps for Al, Ba, Bi, Ca, Co, Cr, Cd, Cu, Fe, Hg, K, Li, Mg, Mn, Mo, Na, Ni, Pb, Sb, Sn, Sr, Ti, Zr, Ag, As, Se, Si, Te, V, W, B, P, Ge, Be, Au, Rb, Cs
Labmate LMAAS-A109 is suitable for both ultra-trace and high-concentration elemental detection, making it ideal for petrochemical, metallurgical, mining, geological, food, and pharmaceutical applications.
-