Labmate Atomic Absorption Spectrophotometer LMAAS-A106

Labmate Atomic Absorption Spectrophotometer LMAAS-A106

Labmate Atomic Absorption Spectrophotometer LMAAS-A106 features a double-beam optical system with flame atomization, delivering high-stability and ultra-sensitive elemental analysis from 190 to 900 nm. It incorporates D2 and self-absorption background correction, automated acetylene and airflow control, and a vertical 8-lamp turret for multi-element detection. Fully PC-controlled, it streamlines data acquisition, analysis, and reporting.

  • Product Info

    Specifications

    Parameter Specification
    Optical Type Double beam
    Atomizer Flame atomizer
    Monochromator Czerny-Turner type, focal length 350 mm
    Wavelength Range 190–900 nm
    Wavelength Accuracy ±0.15 nm
    Wavelength Repeatability ±0.05 nm
    Grating Holographic diffraction grating, 1800 lines/mm
    Slits 0.1, 0.2, 0.4, 0.7, 1.4, 2.0 nm
    Lamp Holder Automated 8-lamp turret
    Detector UV-sensitive photomultiplier tube
    Reading Mode Transmittance (T), Absorbance (A), Concentration (C)
    Photometric Range 0–125 %, -0.1 to 3.00 A
    Static Baseline Drift (Cu) <0.002 A/30 min
    Dynamic Baseline Drift <0.004 A/15 min
    Background Correction D2 and self-absorption
    Characteristic Concentration (Cu) <0.035 µg/ml
    Detection Limit (Cu) <0.004 µg/ml
    Repeatability (Cu) RSD <0.5 %
    Acetylene Flow Control Auto 12-level
    Air Flow Control Auto 4-level
    Burner Head 100 mm titanium alloy, self-adjusting
    Safety Protection Flame sensor, gas leak sensor, gas pressure sensor
    Software RGWIN AAS software package
    Analytical Methods Flame AA, Flame AE, Hydride generation
    Concentration Calculation Standard curve, Standard Addition, Interpolation
    Repeated Measurement Times 1–30 times, Average, SD, RSD
    QA/QC Functions Correlation coefficient, SD & RSD
    Communication Port Standard RS-232
    Working Environment Temp 10–35 °C, Humidity <85 %
    Power Supply 110/220 V, 50/60 Hz
    Dimension (W×D×H) 850 × 650 × 550 mm
    Weight 100 kg

    Features

    • Titanium alloy self-adjusting burner

    • Automated slit selection

    • High-performance glass nebulizer

    • Corrosion-resistant premix chamber

    • Report printing

    • Vertical 8-lamp turret

    Standard Accessories

    Accessory Unit Quantity
    Main unit Each 1
    Power cable Each 1
    Data cable Each 1
    Screwdriver Each 1
    Cu Hollow cathode lamp Each 1
    Air compressor Each 1
    6 mm orange acetylene tube (10 m) Each 1
    6 mm transparent air tube (10 m) Each 1
    USB (manual and software) Each 1
    Drain tube (2 m) Each 1
    Acetylene pressure-reducing valve connector Each 1
    5 A fuse Each 3
    Ignition filament Each 5

    Optional Accessories

    Model No Accessory Unit Quantity
    LMAAS-A106-H1 Hybrid Generator Each 1
    LMAAS-A106-Q1 Quiet Air Compressor Each 1
    LMAAS-A106-B1 50 mm Nitrous Oxide Burner Each 1
    LMAAS-A106-N1 Glass Nebulizer Each 1
    LMAAS-A106-A1 Auto Sampler Each 1
    LMAAS-A106-M1 N2O Module Each 1
    LMAAS-A106-D1 Deuterium Lamp Each 1
    LMAAS-A106-L1 Hollow Cathode Lamp (Al, Ba, Bi, Ca, Co, Cr, Cd, Cu, Fe, Hg, K, Li, Mg, Mn, Mo, Na, Ni, Pb, Sb, Sn, Sr, Ti, Zr) Each 1
    LMAAS-A106-L2 Hollow Cathode Lamp (Ag, As, Se, Si, Te, V, W) Each 1
    LMAAS-A106-L3 Hollow Cathode Lamp (B, P, Ge, Zr) Each 1
    LMAAS-A106-L4 Hollow Cathode Lamp (Be) Each 1
    LMAAS-A106-L5 Hollow Cathode Lamp (Au) Each 1
    LMAAS-A106-L6 Hollow Cathode Lamp (Rb) Each 1
    LMAAS-A106-L7 Hollow Cathode Lamp (Cs) Each 1

    Applications

    Labmate Atomic Absorption Spectrophotometer LMAAS-A106 is ideal for quantifying metal elements in environmental samples, food, pharmaceuticals, biological fluids, mining, agriculture, petrochemicals, and forensic laboratories.

Heading 6

Related Products

bottom of page