Labmate Atomic Absorption Spectrophotometer LMAAS-A103 features a double-beam optical system with a broad wavelength range of 185–900 nm. It integrates both flame and graphite furnace atomizers, offering ultra-sensitive detection and high-throughput efficiency. The system includes an automatic eight-lamp position turret to accommodate a wide range of elements.

  • Product Info

    Specifications

    Parameter Specification
    Optical System Double Beam
    Monochromator Czerny-Turner, focal length 350 mm
    Grating 1800 lines/mm, blaze wavelength 250 nm
    Spectral Bandwidth 0.1, 0.2, 0.4, 0.7, 1.4, 2 nm, automated slit selection
    Wavelength Range 185–900 nm
    Wavelength Accuracy 0.15 nm
    Wavelength Repeatability ≤0.05 nm
    Spectral Bandwidth Deviation ±0.02 nm
    Lamp Stand 8
    Element Lamp Type Cu lamp
    Reading Mode Transmittance, absorbance, concentration
    Photometric Range 0–125 %, -0.1 to 3.00 A
    Static Baseline Drift (Cu) ±0.003 A/30 min
    Dynamic Baseline Drift (Cu) ±0.005 A/15 min
    Background Correction Deuterium lamp ≥40× (1 Abs)
    Characteristic Concentration ≤0.035 μg/ml
    Detection Limit (Cu) ≤0.004 μg/ml
    Repeatability (Cu) RSD ≤0.5 %
    Acetylene Flow Control Auto 12-Level
    Air Assist Control Auto 4-Level
    Burner Lift Automatic
    Burner Head Titanium 100 mm
    Nebulizer High-efficiency glass
    Spray Chamber Corrosion-resistant material
    Safety Protection Auto cutoff for low pressure, flame out, power failure, or burner mismatch
    Characteristic Amount Cd ≤0.8 pg, Cu ≤20 pg
    Detection Limit Cd ≤1 pg, Cu ≤5 pg
    Repeatability (Cd) RSD ≤2.5 %
    Graphite Furnace Heating Range Room temperature to 3000 °C
    High-Power Heating Range 1500–3000 °C
    Heating Rate Max 2000 °C/s
    Atomization Modes Light-controlled, time-controlled, general heating
    Protective Gas Flow Outside: 1 L/min, Inside: adjustable 0/50/200/250 ml/min
    Data Processing Monitors cooling water flow, protective gas pressure, furnace temp, power supply temp, graphite furnace installation
    External Connect Method selection, concentration calculation, repeat measurements, report printing
    Ambient Temp 10–30 °C
    Ambient Humidity 40–85 %
    Power 220 V, 50/60 Hz
    Dimension (W×D×H) 830 × 650 × 560 mm
    Net Weight 110 kg

    Features

    • Automatic switchable test modes

    • Integrated titanium burner

    • Multiple alarm functions including acetylene leakage monitoring

    • Automatic wavelength scanning and peak search

    • Argon gas and pressure regulators must be provided by user

    Standard Accessories

    • Software

    • Cd hollow cathode lamp

    • Pipette

    Optional Accessories

    Model No Accessory Name Unit Quantity
    LMAAS-A103-A1 Argon pressure reducer Each 1
    LMAAS-A103-L1 Laughing gas module Each 1

    Applications