top of page
Kirsch LABO 288 ULTIMATE Laboratory Refrigerator

Kirsch LABO 288 ULTIMATE Laboratory Refrigerator

The LABO 288 ULTIMATE provides the highest level of storage security and thermal precision for professional laboratory environments. Meeting the rigorous DIN 13277 standards, this unit combines an elegant, intuitive interface with advanced refrigeration technology to ensure the long-term integrity of your most sensitive samples.

 

Advanced Thermal Control and Efficiency

 

At the heart of the LABO 288 ULTIMATE is the renowned KIRSCH-Airflow-Concept, which minimizes temperature gradients within the interior to provide world-class thermal uniformity. The unit also features an innovative refrigeration system utilizing inverter technology, which significantly reduces energy consumption and lowers total operating costs while minimizing your laboratory's environmental footprint.

  • PRODUCT INFO

    Intuitive Interface and Secure Access

    Designed for modern facility management, the LABO 288 ULTIMATE features an elegant, glass capacitive touchscreen. This interface allows for effortless monitoring and control of the storage environment. Integrated access control ensures that only authorized personnel can handle critical samples, providing an additional layer of security and traceability for your laboratory operations.

    Engineered for Reliability

    Built for long-term, low-maintenance service, this refrigerator is optimized for whisper-quiet operation, ensuring it integrates discreetly into active research settings. Automatic defrosting and intelligent management features mean the unit requires minimal manual oversight, allowing your team to focus on their work with the confidence that their samples are being maintained in a stable, secure, and highly efficient environment.

    Key Features

    • Ultimate Thermal Uniformity: Features the KIRSCH-Airflow-Concept to eliminate temperature fluctuations.

    • Inverter Efficiency: Advanced refrigeration technology significantly reduces energy use and costs.

    • Capacitive Glass Touchscreen: Elegant, user-friendly interface for advanced control and monitoring.

    • Secure Access Management: Integrated access control to secure your sensitive samples.

    • Professional Organization: 3 grids included for organized sample storage.

Heading 6
Equipment

According to DIN 13277

The DIN 13277 standard for medical refrigerators is designed to ensure the correct storage of medicines that require refrigeration in the healthcare sector. This standard specifies ten requirements that a medical refrigerator must fulfil in order to ensure that the effectiveness of the stored medication is maintained. In addition, the DIN standard not only serves to ensure correct storage, but also to protect the medication from unauthorized access and to comply with occupational health and safety guidelines regarding noise protection.


Reduced energy consumption

Most of our devices now have a refrigeration machine with inverter technology. Reduced energy consumption and longevity are at the heart of this innovative system. This reduces your operating costs and protects the environment. Thanks to the excellent temperature stability, your refrigerated products remain safely cooled at all times, even when the doors are opened and after defrosting. Benefit from quiet operation and low maintenance requirements.


Trust the market leader

World's lowest temperature deviations from the warmest to the coldest storage location thanks to PRO-ACTIVE control & KIRSCH air-guidance concept.




Reliable frost protection

Protection against sub-zero temperatures. The refrigeration machine is switched off via the electronics.




Conformity

  • DIN EN ISO 9001

  • DIN 13277


KIRSCH aerial guidance concept

  • The world's smallest temperature differences between the hottest and coldest storage location thanks to PRO-ACTIVE monitoring and control. KIRSCH air traffic control concept

  • PRO-ACTIVE monitoring: continuous, proactive monitoring of performance data and alerting in the event of deviations

  • Precise temperature control thanks to two PT-1000 temperature sensors

  • Cooling by air circulation

  • Silent fan


Concept of ergonomics

  • Automatic defrosting and evaporation of condensation water

  • Ergonomic door opener

  • Flexible interior design

  • Height-adjustable grids


Security and digital documentation

  • Frost protection

  • Electronic door lock

  • Optical and acoustic alarm signals, even in the event of a power failure

  • Minimum/maximum temperature memory

  • Potential-free contact for connection to remote warning systems

  • Digital data documentation via network (PC-KIT-NET) and KIRSCH Datanet software


Ultimate Line

  • Simple operation thanks to capacitive glass touchscreen

  • Operation is also possible with laboratory gloves

  • Operation via remote access is possible (with network connection)

  • Access control with RFID and/or code with protocol and integrated user management

  • Alarm and status messages in plain text

  • Graphical display of temperature evolution

  • Quick commissioning

  • including the benefits of the PRO-ACTIVE range


Downloads

Product information

Laboratory refrigerator LABO 288 ULTIMATE


Operating instructions

Please note: You will find the information about the refrigerant used in your unit on the type plate inside the unit (R134a or R600a)


Operating instructions LABO 288 ULTIMATE

Additional instructions ULTIMATE

Additional instructions PC-KIT-STICK


bottom of page